← Back to Robots
Collaborative Robots and Manipulators

JAKA Zu7

Submit correction
Request a Quote

About JAKA Zu7

JAKA Zu7 is a six-axis collaborative manipulator for part transfer, machine loading and movement between fixtures.


Manufacturer

Key Specifications

Reach
819 mm
Status
ACTIVE
Category
Collaborative Robots and Manipulators
Zu7 arm V11 / Reach
819 mm
Zu7 arm V11 / Humidity
0…90 % RH (Non-condensing.)
Zu7 arm V11 / Mounting
Any orientation
Zu7 arm V11 / Materials
Aluminium alloy, PC
Zu7 axes V11 / J1 range
±360 °
Zu7 axes V11 / J1 speed
180 °/s
Zu7 axes V11 / J2 range
-85…+265 °
Zu7 axes V11 / J2 speed
180 °/s
Zu7 axes V11 / J3 range
±175 °
Zu7 axes V11 / J3 speed
180 °/s
Zu7 axes V11 / J4 range
-85…+265 °
Zu7 axes V11 / J4 speed
180 °/s
Zu7 axes V11 / J5 range
±360 °
Zu7 axes V11 / J5 speed
180 °/s
Zu7 axes V11 / J6 range
±360 °
Zu7 axes V11 / J6 speed
180 °/s
Tool TIO V11 / Connector
M8
Tool TIO V11 / Tool supply
12 /24 V
CAB7/CAB2.1 V11 / Protocols
TCP/IP, Modbus TCP, Modbus RTU
Zu7 arm V11 / Base diameter
158 mm
Zu7 arm V11 / Rated payload
7 kg (Allowable payload depends on the centre-of-mass offset from the flange.)
Zu7 arm V11 / Repeatability
±0.02 mm
CAB7/CAB2.1 V11 / DI/DO mode
PNP
CAB7/CAB2.1 V11 / I/O supply
24 V
Tool TIO V11 / Analog inputs
2 pcs
Zu7 arm V11 / Arm protection
IP54
Zu7 arm V11 / Flange buttons
FREE / POINT
CAB2.1 internal IPC V11 / CPU
Intel Celeron J1900 (Internal cabinet board.)
CAB2.1 internal IPC V11 / RAM
2 GB (Internal cabinet board.)
Tool TIO V11 / Digital inputs
2 pcs
Zu7 arm V11 / Cleanroom class
Class5 (ISO14644-1:2015 and ISO14644-14:2016.)
CAB7/CAB2.1 V11 / DI low level
0…11 V (With V+=24V.)
CAB7/CAB2.1 V11 / Mains supply
100…240 V AC
CAB7/CAB2.1 V11 / P10 Ethernet
Three-position enabling device network interface
Tool TIO V11 / Digital outputs
2 pcs
Tool TIO V11 / Serial channels
2 × RS-485 (TIO3.0; multiplexed with digital outputs and analog inputs.)
Zu7 arm V11 / Base programming
Graphical programming and drag teaching
Zu7 arm V11 / Handheld control
Emergency stop; power; enabling; start/stop; reset; pause/resume; lock
Zu7 arm V11 / Storage humidity
20…85 % RH (Avoid condensation and mould.)
CAB7/CAB2.1 V11 / DI high level
15…30 V (With V+=24V.)
CAB7/CAB2.1 V11 / Safety inputs
EI1/EI2, SI1/SI2 (Dual-channel emergency and protective stop.)
Tool TIO V11 / TIO cable length
400 mm
Zu7 arm V11 / Maximum TCP speed
2.5 m/s
CAB7/CAB2.1 V11 / Cabinet weight
15.4 kg
CAB7/CAB2.1 V11 / Compatible arm
JAKA Zu7
CAB7/CAB2.1 V11 / Digital inputs
16 pcs
Zu7 arm V11 / Degrees of freedom
6 DOF
CAB2.1 internal IPC V11 / Storage
64 GB (Internal cabinet board.)
CAB7/CAB2.1 V11 / Digital outputs
16 pcs
CAB7/CAB2.1 V11 / Internal USB P9
USB3.0 (Internal debugging, not an external user port.)
CAB7/CAB2.1 V11 / Mains frequency
50…60 Hz
Tool TIO V11 / Analog input range
0…10 V (TIO3.0.)
Zu7 arm V11 / Ambient temperature
0…50 °C (Preheat before use below10°C.)
Zu7 arm V11 / Storage temperature
-10…50 °C
CAB7/CAB2.1 V11 / Cabinet material
Powder-coated carbon steel
CAB7/CAB2.1 V11 / High-speed input
P6: conveyor encoder
CAB7/CAB2.1 V11 / P5 analog supply
5 V (100mA maximum.)
CAB7/CAB2.1 V11 / Safety I/O pairs
DI1+DI9 …DI8+DI16; DO1+DO9 …DO8+DO16 (Dual-channel configuration.)
CAB7/CAB2.1 V11 / Serial interface
RS-485, P7
Tool TIO V11 / Digital input modes
PNP / NPN (TIO3.0.)
Tool TIO V11 / Peak supply current
2 A (TIO3.0.)
Zu7 arm V11 / Button and indicator
Pause/resume; ring-shaped status indicator
Zu7 arm V11 / Programming terminal
PC, tablet or smartphone
CAB2.1 internal IPC V11 / Board VGA
1 pcs (Internal cabinet board.)
CAB7/CAB2.1 V11 / P6 encoder supply
5 V (100mA maximum.)
Tool TIO V11 / Digital output modes
PNP / NPN / push-pull (TIO3.0.)
Zu7 installation V11 / Base force X
480 N (Separate maxima cannot occur simultaneously.)
Zu7 installation V11 / Base force Y
480 N (Separate maxima cannot occur simultaneously.)
Zu7 installation V11 / Base force Z
500 N (Separate maxima cannot occur simultaneously.)
Zu7 installation V11 / Flange depth
32.5 mm
CAB2.1 internal IPC V11 / Board HDMI
1 pcs (Internal cabinet board.)
CAB7/CAB2.1 V11 / Analog I/O voltage
0…10 V
CAB7/CAB2.1 V11 / Cabinet protection
IP44
CAB7/CAB2.1 V11 / Dimensions W×D×H
410 ×235 ×307 mm
CAB7/CAB2.1 V11 / External I/O cable
<30 m (Front-panel P1–P8 wiring harnesses, table 6-14.)
CAB7/CAB2.1 V11 / External V+ supply
10…35 V (Requires the appropriate jumper configuration.)
CAB7/CAB2.1 V11 / Mains cable length
3 m
Zu7 arm V11 / Additional programming
SRCI; offline
Zu7 arm V11 / Handheld control cable
6 m
Zu7 arm V11 / Peak power consumption
2000 W
Zu7 arm V11 / Robot connection cable
6 m
Zu7 installation V11 / Base torque X
440 N·m (Separate maxima cannot occur simultaneously.)
Zu7 installation V11 / Base torque Y
440 N·m (Separate maxima cannot occur simultaneously.)
Zu7 installation V11 / Base torque Z
400 N·m (Separate maxima cannot occur simultaneously.)
CAB2.1 internal IPC V11 / Memory type
DDR3L (Internal cabinet board.)
CAB7/CAB2.1 V11 / Cabinet temperature
0…50 °C
CAB7/CAB2.1 V11 / Industrial networks
PROFINET, Ethernet/IP (With JAKA App1.7.)
Tool TIO V11 / Digital output current
≤1 A (TIO3.0.)
Zu7 arm V11 / Collaborative operation
GB11291.1-2011 (The complete application requires a risk assessment.)
Zu7 arm V11 / Weight including cables
22 kg
Zu7 installation V11 / Base fasteners
4 ×M8
Zu7 installation V11 / Tool fasteners
4 ×M6,6mm depth
CAB2.1 internal IPC V11 / Board USB2.0
3 pcs (Internal cabinet board.)
CAB2.1 internal IPC V11 / Board USB3.0
1 pcs (Internal cabinet board.)
CAB7/CAB2.1 V11 / Analog current input
4…20 mA
CAB7/CAB2.1 V11 / Bottom Ethernet port
Gigabit; dynamic IP
CAB7/CAB2.1 V11 / Remote power control
P7: ON/OFF (5…24V signals; internal5V supply,100mA maximum.)
CAB2.1 internal IPC V11 / CPU frequency
1.99 GHz (Internal cabinet board.)
CAB7/CAB2.1 V11 / Analog current output
0…20 mA
CAB7/CAB2.1 V11 / Ventilation clearance
≥100 mm (Left, right and above.)
Zu7 arm V11 / Average power consumption
350 W
Zu7 installation V11 / Tool bolt circle
50 mm
CAB2.1 internal IPC V11 / Board Ethernet
2 pcs (Internal cabinet board.)
Tool TIO V11 / Continuous supply current
1 A (TIO3.0.)
Zu7 arm V11 / Long-term storage humidity
45…65 % RH (Recommended range.)
CAB7/CAB2.1 V11 / Default analog I/O mode
0…10V input
Zu7 arm V11 / EU page nominal consumption
350 W
Zu7 installation V11 / Base through holes
9 mm
Zu7 installation V11 / Tool locating hole
6 mm (Tolerance+0.012/0mm.)
Zu7 installation V11 / Base locating holes
8 mm
Zu7 installation V11 / Cable carrier speed
≤2 m/s
CAB7/CAB2.1 V11 / Internal24V total current
≤1.5 A (Internal supply;≤1A recommended.)
Zu7 arm V11 / Long-term storage temperature
25±10 °C (Recommended range.)
Zu7 installation V11 / Mounting screw grade
12.9 (Recommended grade; engagement1.5…2 nominal diameters.)
Zu7 installation V11 / Robot cable diameter
10.2 mm
Zu7 installation V11 / Maximum flange torque
34 N·m
Zu7 installation V11 / Base tightening torque
40 N·m
CAB7/CAB2.1 V11 / Configurable analog channels
2 pcs
Zu7 installation V11 / Flange outside diameter
81 mm
CAB7/CAB2.1 V11 / Single digital output current
≤1 A
V11 system contents and connections / TIO cable
1 pcs
Zu7 installation V11 / Mounting plate thickness
≥20 mm (Steel plate recommended.)
Zu7 installation V11 / Minimum cable bend radius
81.6 mm
Zu7 installation V11 / Cable carrier acceleration
≤5 m/s²
V11 system contents and connections / Cabinet and key
1 set (V11 full system; CAB7 is the cabinet model listed for this arm.)
Zu7 installation V11 / Mounting plate torque capacity
3000 N·m
V11 system contents and connections / Handheld control
1 pcs
V11 system contents and connections / V11 cabinet WLAN
Built-in wireless module connects the operating terminal to the cabinet WLAN. (The network name is the cabinet number. An external router is an alternative connection method.)
V11 system contents and connections / Cabinet power cable
1 pcs
V11 system contents and connections / P5 / Analog grounding
Analog I/O is not galvanically isolated from the cabinet; the equipment and cabinet use a common ground.
V11 system contents and connections / P7 / Remote switching
ON and OFF inputs must not be shorted simultaneously.
V11 system contents and connections / Arm in complete system
1 pcs (V11 full-system packing list.)
V11 system contents and connections / P1–P8 wiring harness
UL1007 #20 AWG (Table 6-14, front-panel wiring; length less than 30 m.)
V11 system contents and connections / P7 / RS485 termination
120 Ω (Recommended terminating resistor; YAGEO MF0207FTE52-120R is specified.)
V11 system contents and connections / Robot connection cable
1 pcs
V11 system contents and connections / Complete-system documents
JAKA certificate, warranty card and safety leaflet: 1 each. (Documents in the complete-system V11 packing list.)
V11 system contents and connections / P6 / Differential encoder
Inputs A+/A−, B+/B−, Z+/Z−; DG is isolated from internal GND.
V11 system contents and connections / TIO3.0 supply configuration
12/24 V; the supply can be enabled or disabled through configuration.
V11 system contents and connections / Default V11 cabinet generation
CAB2.1 (V11 states CAB2.1 is the default; MiniCab has a separate manual.)

Verified ecosystem

Software and resources

Official links and community projects are shown separately. Every published relationship has reviewable evidence.

0
verified official resources
0
verified compatible projects
0
public maintainers
No activity yet
latest verified ecosystem activity

Projects are ordered only within this robot ecosystem using verified compatibility, GitHub freshness and activity, and accepted community reports. This is not a global RobotSpace score.

Official resources

No first-party resource has been independently verified yet. Unverified catalog links are not shown as official.

Official software

No official software project has been verified yet.

Community projects

No verified community project has been linked yet.

Developers and contributors

No public maintainer profile is linked yet.

Verified activity

No verified project activity is available.

This ecosystem is still empty

The robot page remains useful for specifications while official resources and compatible projects are being verified.

Imported from the Unibot owner catalog · Not independently verified · Imported 2026-11-11 · Unibot source · Methodology